The SUTX40K SmartOnline® SUTX Series 3-Phase 220/380V, 230/400V or 240/415V 40kVA 40kW On-Line Double-Conversion UPS provides battery backup and AC power protection against power disturbances that can damage electronics or destroy data. It’s recommended for critical data center, LAN/WAN and distributed server room applications.
The SUTX40K’s Voltage and Frequency Independent (VFI) design allows continuous operation at any supported voltage at either 50 or 60 Hz. Zero transfer time to battery mode ensures no disruption to the attached loads. Automatic and Manual Bypass keeps connected equipment powered, even during overloads and UPS maintenance.
IGBT inverter technology produces output power with 1% total harmonic distortion (THD) to keep connected equipment functioning at its peak. A 3:1 crest factor safely supports a variety of loads, even those with wildly fluctuating power demands.
Managing the SUTX40K is simplified through the multi-language LCD interface, which displays critical operating conditions and diagnostic data, such as battery and load status. Four LEDs indicate bypass, line, battery and fault modes. A built-in card slot supports the optional WEBCARDLX network management card for network interface and remote monitoring and control.
VFI True On-Line Double-Conversion 3-Phase UPS System
Provides fully regulated sine wave AC output for critical data center, LAN/WAN and distributed server room applications
+/-1% output voltage regulation in online and battery modes
1.0 unit power factor offers 40kVA/40kW output capacity, allowing for more connected devices
Supports 380/220V, 400/230V or 415/240V at 50/60 Hz in continued operation
Wide input voltage window (228–477V) minimizes battery use and prolongs battery life
Reliable Battery Backup with Expandable Runtime
Supports half load for 15.5 min. and full load for 5.9 min. with standard internal battery
Zero transfer time suitable for advanced network applications
Expandable runtime with optional external battery packs, such as BP480V09
Restarts automatically after lengthy power outages
IGBT Inverter Technology
Produces output power with 1% THD to keep connected equipment functioning at its peak
Low <4% THDi input rating and advanced IGBT rectifier enables 1:1 generator sizing, eliminating costly oversizing requirements for generators, breakers and cables
Paralleling Capability
Connect up to 4 units in parallel configuration for fault tolerance or increased capacity up to 160kVA
Automatic and Manual Bypass
Allows maintenance without removing power from attached loads
Increases system reliability
ECO Mode
Operates at efficiency levels as high as 99% when input line conditions are favorable
Optional Network Management Card
Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
Communications Ports
DB9 port enables data-saving unattended shutdown when used with PowerAlert software (available via free download at tripplite.eaton.com/products/power-alert)
EPO port supports emergency shutdown in large facilities
Single, Compact Cabinet
May be installed with either single or dual AC sources for increased availability
The SUTX40K’s Voltage and Frequency Independent (VFI) design allows continuous operation at any supported voltage at either 50 or 60 Hz. Zero transfer time to battery mode ensures no disruption to the attached loads. Automatic and Manual Bypass keeps connected equipment powered, even during overloads and UPS maintenance.
IGBT inverter technology produces output power with 1% total harmonic distortion (THD) to keep connected equipment functioning at its peak. A 3:1 crest factor safely supports a variety of loads, even those with wildly fluctuating power demands.
Managing the SUTX40K is simplified through the multi-language LCD interface, which displays critical operating conditions and diagnostic data, such as battery and load status. Four LEDs indicate bypass, line, battery and fault modes. A built-in card slot supports the optional WEBCARDLX network management card for network interface and remote monitoring and control.
VFI True On-Line Double-Conversion 3-Phase UPS System
Provides fully regulated sine wave AC output for critical data center, LAN/WAN and distributed server room applications
+/-1% output voltage regulation in online and battery modes
1.0 unit power factor offers 40kVA/40kW output capacity, allowing for more connected devices
Supports 380/220V, 400/230V or 415/240V at 50/60 Hz in continued operation
Wide input voltage window (228–477V) minimizes battery use and prolongs battery life
Reliable Battery Backup with Expandable Runtime
Supports half load for 15.5 min. and full load for 5.9 min. with standard internal battery
Zero transfer time suitable for advanced network applications
Expandable runtime with optional external battery packs, such as BP480V09
Restarts automatically after lengthy power outages
IGBT Inverter Technology
Produces output power with 1% THD to keep connected equipment functioning at its peak
Low <4% THDi input rating and advanced IGBT rectifier enables 1:1 generator sizing, eliminating costly oversizing requirements for generators, breakers and cables
Paralleling Capability
Connect up to 4 units in parallel configuration for fault tolerance or increased capacity up to 160kVA
Automatic and Manual Bypass
Allows maintenance without removing power from attached loads
Increases system reliability
ECO Mode
Operates at efficiency levels as high as 99% when input line conditions are favorable
Optional Network Management Card
Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
Communications Ports
DB9 port enables data-saving unattended shutdown when used with PowerAlert software (available via free download at tripplite.eaton.com/products/power-alert)
EPO port supports emergency shutdown in large facilities
Single, Compact Cabinet
May be installed with either single or dual AC sources for increased availability
Battery | |
Battery recharge time | 8.1 h |
Cold start | Y |
Typical backup time at full load | 5.9 min |
Typical backup time at half load | 15.5 min |
Design | |
Certification | CE |
Cooling type | Active |
Country of origin | China |
Display type | LCD |
Form factor | Tower |
Housing material | Steel |
Product colour | Black |
Features | |
Audible alarm modes | Low battery alarm, Overload alarm |
Audible alarm(s) | Y |
Crest factor | 3:1 |
EMI/RFI noise filtering | Y |
Hot-swap battery | Y |
Input frequency | 50/60 Hz |
Input operation voltage (max) | 477 V |
Input operation voltage (min) | 228 V |
Number of input phases | 3 |
Output frequency | 50/60 Hz |
Output operation voltage (max) | 415 V |
Output operation voltage (min) | 220 V |
Output power | 40000 W |
Output power capacity | 40 kVA |
Output power factor | 1 |
Output voltage regulation | +/-1% |
Power factor | 1 |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Logistics data | |
Master (outer) case gross weight | 420 kg |
Master (outer) case height | 1640.8 mm |
Master (outer) case length | 1010.9 mm |
Master (outer) case width | 723.9 mm |
Products per master (outer) case | 1 pc(s) |
Operational conditions | |
Operating relative humidity (H-H) | 0 - 95% |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -20 - 40 °C |
Power | |
Surge energy rating | 8320 J |
Sustainability | |
Sustainability certificates | RoHS |
Weight & dimensions | |
Depth | 840.7 mm |
Height | 1399.5 mm |
Package depth | 1010.9 mm |
Package height | 1640.8 mm |
Package weight | 420 kg |
Package width | 723.9 mm |
Weight | 383 kg |
Width | 490.2 mm |
Tripp Lite SUTX40K SmartOnline SUTX Series 3-Phase 220/380V, 230/400V, 240/415V 40kVA 40kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option
- Brand: Tripp-Lite
- Product Code: SUTX40K
- Availability: In Stock
-
$16,343.32